Blood Collection Tubes Additives Chart

Below is result for Blood Collection Tubes Additives Chart in PDF format. You can download or read online all document for free, but please respect copyrighted ebooks. This site does not host PDF files, all document are the property of their respective owners.

UPDATED PHLEBOTOMY PROCEDURES

Send Blood Collection Tubes to the Proper Laboratories: Appropriately labeled blood collection tubes should be sent to laboratories designated to perform the required testing procedures. Maintain proper transport conditions to preserve specimen integrity. 56 8.17

Order of blood draw: Opinion Paper by the European Federation

includes sample collection (phlebotomy). National and international (WHO, CLSI) guidelines recommend that the order of draw of blood during phlebotomy should be blood culture/sterile tubes, then plain tubes/gel tubes, then tubes containing additives. This prevents contamination of sample tubes with additives from previous tubes that

Test Tube Guide and Order of Draw - Guthrie

The discard tube is used to fill the dead space in the tubing to ensure proper blood-to-additive ratio in the citrate tube. **Mix blood collection tubes by inverting 8 to 10 times. Coagulation testing.

Blood Test Tubes Guide Chart

Tube Chart Tube Chart Venous Blood Collection Tubes * Also available in pediatric or low draw volumes of 2mL or less. Cap Colors 8-10 Hematology Immunohematology Molecular Diagnostics Viral Markers K 3 EDTA* K 2 EDTA* No Additive* 5-10 Discard Tube Transport/Storage Immunohematology Viral Markers Sodium Citrate 3.2% (0.109 M)* 4 Coagulation

Specimen Collection Venipuncture Procedure

Order of Draw Tube Stopper Color Rationale for Collection Order Blood cultures (sterile collections) Yellow SPS Sterile media bottle Minimizes chance of microbial contamination Glass non-additive tubes Red Prevents contamination by additives in other tubes Coagulation tubes Light blue The first additive tube in the order

Blood Tube Color Chart - testmenu.com

Mar 13, 2020 Blood Tube Color Chart for specimens submitted to University of Colorado Hospital Laboratory Test Name Alt Spec Add- on Test Name Alt Spec Add- on Test Name Alt Spec Add- on Acute Hepatitis Panel None 2d Basic Metabolic Panel None 3d CBC None 2d Alpha Feto Protein None 2d Complete Metabolic Panel None 3d Blood parasites None N/A

Standard Operating Procedures - UCLA CTSI

Invert blood collection tubes with additives for proper mixture. Do not shake. 14. Apply pressure to the site for approximately 2 to 3 minutes. Pressure may need to be applied for a longer period of time in certain individuals. 15. Tape the gauze pad or a band-aid may be applied to the site. 16. Discard blood contaminated products into the

Specimen Collection Tubes - Quest Diagnostics

Collection Tubes Light blue tubes All plastic tubes other than light blue Clot 30-60 minutes Spin 10-15 minutes Pour into Transport Vial Label with Specimen Type Patient ID Patient ID Patient ID SERUM Do not use gel tubes for toxicology or drug testing * When using a winged blood collection set for venipuncture and a coagulation (citrate) tube

We supply our clients with BD Vacutainer tubes for - M Health

We supply our clients with BD Vacutainer tubes for the collection of blood samples that are sent to us for testing. These tubes contain pre -measured vacuum and pre-measured additives; therefore it is very important that these tubes are filled to the stated fill volume. If you under-fill or over-fill

Blood Specimen Collections

When possible, blood specimen collection tubes should be filled to the maximum volume to ensure proper additive to specimen ratio and quantity of specimen for requested tests. Standard blood specimen collection tubes with additives should be filled with a minimum volume of 1mL of specimen.

Specimen Collection Tubes

Specimen Collection Tubes BLOOD SPECIMENS URINE SPECIMENS Stopper/Label Color Laboratory Use Additives/Inversions at Collection For detection of microbial growth from blood specimens. Soybean-casein digest broth 8 10 gentle inversions unless otherwise noted Culture Bottles For coagulation determinations. Note: Certain tests

Specimen Collection & Handling Guide

Sep 04, 2001 several times (typically at least 8 times). These tubes are centrifuged to separate the plasma from the cells. Whole Blood: Blood drawn into a tube with an anticoagulant additive will not clot if mixed properly. Proper mixing is gentle inversion several times (typically at least 8 times). Whole blood specimens are not centrifuged. Blood

LABORATORY TUBE COLLECTION QUICK REFERENCE GUIDE

Avoid SST® blood collection tube is preferred LACTIC ACID WHOLE BLOOD (NOT ON ICE) GRAY Sodium Fluoride/Potassium Oxalate 8 tube inversions ensure proper mixing of additives with blood. NO CLOTTING TIME REQUIRED LACTIC ACID (ON ICE) PURPLE Spray-coated K2EDTA (plastic) 8 tube inversions required to ensure mixing of

BLOOD COLLECTION TUBES - Catholic Medical Center

Minimum fill indicator represents the minimum volume of blood required for appropriate analysis. A discard tube (without additives) must be used if only a citrate tube is to be drawn using a winged blood collection set. It is important to remove the air from the blood collection set to ensure the proper blood volume is obtained in the tube.

The Center for Phlebotomy Education Presents Know-How How

©2008 Center for Phlebotomy Education, Inc. The world s most dependable source of accurate information on blood specimen collection procedures. www.phlebotomy.com Know-How Know-How How Underfilling Tubes Cheats Patients Y ou re drawing blood into a syringe. Everything is going fine when sud-denly the blood stops flowing. You

COLLECTION TUBES FOR PHLEBOTOMY

Blood collection tubes must be filled in a specific order to avoid specimen contamination from the additive in the preceding tube. The following order of draw is an accepted laboratory standard. 1. Tubes or bottles for blood cultures 2. Light-blue top tubes (sodium citrate) 3. Serum tubes (with or without clot activator) 4.

Blood Cultures - Aerobic & Anaerobic

Collection Materials CSF tray Skin disinfectant Sterile towels or drape Novocaine (0.5 to 1 %), needle, syringe Two lumbar puncture needles, small bore (20 to 22 gauge) with stylet Water manometer Three small, sterile, screw-cap tubes Collection Method Ensure that the patient will be motionless during the procedure. Restrains may be

Specimen Collection and Preparation

blood into a tube containing the proper anticoagulant. Immediately invert the tube gently several times to mix. Unless whole blood is required, separate the plasma from the cells by centrifugation within 30 minutes. Examples Vof anticoagulant collection tubes include the following: green-top (lithium or sodium heparin), lavender-top (EDTA), and

DLO Blood Collection Chart Specimen Handling and Transport

This chart shows the various tube tops used during the collection of DLO lab specimens, including the additive, number of inversions and order of draw¹. 1: Order of Draw and Number of Inversions are for specimens drawn in plastic tubes only. 2: When using a winged blood collection set for venipuncture

Tube Chart - Pathology

Tube Chart Tube Chart Venous Blood Collection Tubes * Also available in pediatric or low draw volumes of 2mL or less. Cap Colors 8-10 Hematology Immunohematology Molecular Diagnostics Viral Markers K 3 EDTA* K 2 EDTA* No Additive* 5-10 Discard Tube Transport/Storage Immunohematology Viral Markers Sodium Citrate 3.2% (0.109 M)* 4 Coagulation

QD IFC single pps - Quest Diagnostics

For serum (no gel) tubes only. For clot to form, keep 10 15 minutes tube at room temper-ature for minimum 30 mins. Do not exceed 60 mins. Blood Collection ORDER OF DRAW MIXING CHART SEPARATION Clot Spin Pour into Transport Vial Label with specimen type and patient ID For other blood, serum or plasma separation instructions, see the

Laboratory Blood Specimen Tube Type Collection Chart

Laboratory Specimen Tube Type Collection Chart Draw in the order shown on the chart from left to right order , Label AT THE BEDSIDE, Timely DELIVERY to the LAB Mix all tubes gently 5-10 times by inverting immediately after collection. Color blocks below correspond to patient bedside visual reference used at SPH following mistake proofing.

Product Catalogue - BD

Critical Care Collection syringes including safety products for arterial blood collection and analysis. An expanding range of Molecular Diagnostic products. The BD Vacutainer® evacuated blood collection system is the most widely-used blood stabilisation tube in the world. CE marked to ensure product quality

BD Vacutainer

K3EDTA requires 8-10 inversions for thorough mixing of blood with the anticoagulant. 1 NCCLS, Evacuated Tubes and Additives for Blood Specimen Collection Fifth Edition; Approved Standard. NCCLS documentation H1-A5, Vol. 23, No. 33, Dec. 2003. 2 International Council for Standardization in Haematology Expert Panel on Cytometry

Tube Guide & Order of Draw - Providence Health & Services

Blood cultures Sodium Citrate (Lt Blue) Coagulation: PT/INR, APTT, Factor Assays, Fibrinogen, D-Dimer ACD (Yellow) Special Tests: HLA Typing No Additive (Red)

Test Tube Chart and Order of Draw Guide Sept 2016

ACD solution B 6ml see lab HLA typing - oncology patients - # of tubes depends supply on patient's WBC count, call blood bank 570-887-4218 request no additive, urine specimen only 5-10ml 70835 urine microalbumin, urine drug screen urine chemistry, urine osmolality

BLOOD CULTURE - bioMérieux

Blood culture series: a group of temporally related blood cultures that are collected to determine whether a patient has bacteremia or fungemia. Blood culture set: the combination of blood culture bottles (one aerobic and one anaerobic) into which a single blood collection is inoculated.

BLOOD COLLECTION - sphcs.org

BLOOD COLLECTION Blood collection supplies will be provided upon request for outpatient testing performed by our laboratories. Vacutainer tubes are available in a variety of sizes and contain various types of additives. The additive can be easily identified by the color of the stopper in the tube.

Contents

We supply our clients with BD Vacutainer tubes for the collection of blood samples that are sent to us for testing. These tubes contain pre -measured vacuum and pre-measured additives; therefore it is very important that these tubes are filled to the stated fill volume. If you under-fill or over-fill

DLO Blood Collection Chart - dlolab.com

This chart shows the various tube tops used during the collection of DLO lab specimens, including the additive, number of inversions and order of draw¹. 1: Order of Draw and Number of Inversions are for specimens drawn in plastic tubes only. 2: When using a winged blood collection set for venipuncture

BD Vacutainer Venous Blood Collection Tube Guide

BD Vacutainer® Venous Blood Collection Tube Guide BD Diagnostics * Preanalytical Systems 1 Becton Drive Franklin Lakes, NJ 07417 USA Invert gently,do not shake ** The performance characteristics of these tubes have not been established for infectious disease testing in general; therefore, users must

Collection of Blood Specimens-Venipuncture

Evacuated Collection Tubes - The tubes are designed to fill with a predetermined volume of blood by vacuum. The rubber stoppers are color coded according to the additive that the tube contains. Various sizes are available. Blood should NEVER be poured from one tube to another since the tubes can have different additives or coatings.

Improving the Collection and Management of Human Samples Used

Syringes/Butterflies/Needles for blood collection Alcohol wipes (used to disinfect the site prior to venipuncture) Urine collection devices Blood tubes/micro-containers Processing supplies Analysis consumables (e.g., analytical reagents) Storage vials Safety

Quest Diagnostics Blood Collection Stopper/Label Color

Quest Diagnostics Specimen Collection Tubes When using a winged blood collection set for venipuncture and a coagulation (citrate) tube is the first specimen to be drawn, a discard tube should be drawn first. The discard tube must be used to fill the blood collection set tubing s dead space with blood but the discard tube does not need to

Blood Collection Tube Top Colors

leukocytes (white blood cells) and thrombocytes (platelets) are stable in EDTA anticoagulated blood for up to 24 hours. Preparation of blood smears should be done within 3 hours after blood collection. EDTA tubes are used for testing whole blood in the clinical laboratory. EDTA K2 tubes are used for testing whole blood in molecular diagnostics.

Vacutainer Tubes - Rush Medical Labs

Tubes/Bottles Tube Label Abbrev. Additive Number of Inversions at Blood Collection (Do Not Shake) General Laboratory Use Volume Draw BLCLT 1 Aerobic and 1 Anaerobic Culture Bottles 5 Blood Culture / requires Adapter Note: A separate venipuncture for trace metal analysis is required if blood cultures are ordered at the same time. 20 mL for tubes

1507.P009.A4 Order of Draw Blood Collection Tubes

B. All tubes must be gently inverted 8 10 times to provide thorough mixing of additives. C. Shaking the tube vigorously may cause hemolysis of the blood (separating of red blood cells). II. Order of Draw for Vacutainer Collection Tubes 1. Blood Culture Bottles Used for bacterial and fungal cultures. Must be drawn first to

Blood Collection and Sample Preparation for Rodents

For survival blood collection, the frequency and quantity of sample collection is dependent on the circulating blood volume and the rate of red blood cell turnover of the animal and varies by species. For mice and rats, the circulating blood volume is approximately 55-70 ml/kg of body weight (1,2).

Plus Plastic Citrate Tube Draw Volume Guide

A discard tube (without additives) must be used if only a citrate tube is to be drawn using a winged blood collection set. It is important to remove the air from the blood collection set to insure the proper blood volume is obtained in the coag tube. Do not fill tubes from other tubes or combine two partially filled citrate tubes.