Blood Collection Tubes Edta

Below is result for Blood Collection Tubes Edta in PDF format. You can download or read online all document for free, but please respect copyrighted ebooks. This site does not host PDF files, all document are the property of their respective owners.

Blood collection for thick or thin blood smears

blood does not well up, gently squeeze the finger. For venous blood obtained by venipuncture: 1. Label collection tubes and pre-cleaned slides (preferably frosted-end) with the patient s name (or other identifier), date and time of collection. 2. Clean the site for blood collection well using 70% alcohol; allow to dry. 3.

COLLECTION TUBES AND DESCRIPTION

COLLECTION TUBES AND DESCRIPTION Brand/Cap Color/Volume Additive Mode of Action Uses BD Red Top (10.0 mL) Clot activator - plastic None - glass Blood clots and the serum are separated by centrifugation. Chemistry, Immunology & Serology, Blood Bank/ crossmatch BD Gold Top (5.0 mL) Clot activator and gel for serum separator

Specimen Collection Tubes - Quest Diagnostics

Specimen Collection Tubes BLOOD SPECIMENS URINE SPECIMENS Stopper/Label Color Laboratory Use Additives/Inversions at Collection For detection of microbial growth from blood specimens. Soybean-casein digest broth 8-10 gentle inversions unless otherwise noted Culture Bottles For coagulation determinations. Note: Certain tests

Blood Collection and Sample Preparation for Rodents

Blood Collection and Sample Preparation Definitions and sample preparation Blood samples containing an anticoagulant such as EDTA start to degrade as soon as the blood is outside of the animal. To help minimize this blood should be kept refrigerated and submitted for sampling as soon as possible.

QD IFC single pps - Quest Diagnostics

EDTA Lavender 8 10 Citrate Light Blue 3 4 SST® with gel Red/Black 5 Serum Red 5 Sodium Fluoride Gray 8 10 Heparin Green 8 10 For serum (no gel) tubes only. For clot to form, keep 10 15 minutes tube at room temper-ature for minimum 30 mins. Do not exceed 60 mins. Blood Collection ORDER OF DRAW MIXING CHART SEPARATION Clot

Specimen Collection, Handling, Transport and Processing

Excessive delay between specimen collection and receipt in the laboratory Blood specimens collected in EDTA might be rejected for culture as these inhibit growth of MTB Tissue or abscess material in formalin Gastric lavage fluid if pH not adjusted within 1 hour of collection 22

Specimen Collection Procedures and Policies

o Additive tubes: 1) Green top tubes with or without gel (heparin); 2) Purple top (EDTA) tube; 3) Gray top (oxalate/fluoride) tube (glucose); 4) Yellow (ACDC) tube Blood cultures → Light Blue → Red, Gold or Speckled → Green → Lavender → Gray → Yellow ACDC 5. Note: When using a winged blood collection set for venipuncture and a

Guide to Blood Collection Tubes - King's College Hospital

Safety Blood Collection Sets with Luer Adapter and Holder 21G needle KFK 137 23G needle KFK 138 Safety Blood Culture Collection Sets with Blood Culture Bottle Adapter 21G needle KFK 416 23G needle KFK 417 9ml KFK 076 HIVandHCVviralloadtesting, VirologyMolecularPCR EDTA VACUETTE ® products and ordering codes Ensuretube filledto indicated mark

Neonatal and Paediatric Containers for Blood Collection

BLOOD SCIENCES DEPARTMENT OF BLOOD SCIENCES Title of Document: Neonatal and Paediatric Containers for Blood Collection Q Pulse Reference No: OBS/FT017 Version N : 2 3 of 5 2) Paediatric Outpatients only. Refer to the Standard Vacutainer BD collection tubes in Appendix I and available on Severn Pathology Website with the exception of:

blood tubes and labeling guidelines

collection tube. Whole blood should not be frozen. EDTA whole blood = Lavender (purple) top tube Label this tube with owner name, animal ID, and as EDTA whole blood. This tube (plus 2 blood smears) should be submitted for a hemogram without separation or freezing but should be kept cool. Also this sample is required if a blood sample is being

WHO Blood collect

with highly infectious blood-borne pathogens (e.g. Ebola) Step 1a : Assemble equipment for collecting blood: Laboratory sample tubes for blood collection (sterile glass or plastic tubes with rubber caps, vacuum-extraction blood tubes, or glass tubes with screw caps). EDTA tubes are preferred. Blood sampling systems (Needle and syringe system,

Laboratory Quick Reference Guide to Test Orders

collection. If unable to meet these requirements, patients for this test must be referred to a Health PEI Hospital Specimen Collection Center for collection. Centrifuge and aliquot serum to a transport tube; Freeze immediately. Collect as routine venipuncture. Allergens Allergens Blood 6 mL Red Store and Ship Refrigerated Department: Immunology

Diagnostic Specimen Collection Guide

Prior to specimen collection, check the expiration date on all supplies. Note that tubes expire the last day of the expiration month. Draw correct volume of blood by allowing the vacuum in the tube to be exhausted. Refer to Directory of Services for complete listing of tests and corresponding specimen requirements. Draw Volume: 3.0 mL

3.7.2 Collection, Processing, and Shipping of Blood Samples

Blood collection tubes: - two 10 mL EDTA tubes (BD 366457) - two 10 mL red-topped serum tubes (BD 366430) - one 4.5 mL citrate tubes (BD 366415) - one 5 mL SCAT-I (provided by CBAL) - two 8 mL CPT (provided by CBAL) For Blind Duplicate Samples: 5 mL serum (B-D 366534) and 5 mL EDTA (B-D 366452) tubes Alcohol prep pads

Laboratory Manual and Review on Clinical Pathology

Short filled tube has an excessive amount of EDTA relative to the blood volume. Short filled tubes cause a false increase in total plasma protein content and a false decrease in PCV and RBC count. Figure 2: Collection materials for hematological assessment include syringe, needles, and purple topped collection tubes that contain EDTA.

BIOTIME SARS-CoV-2 IgG/IgM Rapid Qualitative Test

The specimen collection container should be venous blood collection tubes for serum or EDTA anticoagulant tube for plasma and whole blood. 4. Sample collection:

A Cross-Talk between the Erythrocyte L-Arginine/ADMA/Nitric

Jul 04, 2021 2.3. Blood Sample Collection Forty-four milliliters of peripheral blood was collected using the Sarstedt S-Monovette® system (Sarstedt AG & Co., Nümbrecht, Germany). The sample (1.6mg EDTA/mL blood) tubes within 30 min after the collection, were centrifuged at 1000 g for 15min at 4 C and stored at 80 C until further analysis.

BD Vacutainer Venous Blood Collection Tube Guide

BD Vacutainer® Venous Blood Collection Tube Guide BD Diagnostics * Preanalytical Systems 1 Becton Drive Franklin Lakes, NJ 07417 USA Invert gently,do not shake ** The performance characteristics of these tubes have not been established for infectious disease testing in general; therefore, users must

1507.P009.A4 Order of Draw Blood Collection Tubes

Pink top K3 EDTA tube used for testing in Blood Bank (blood typing and cross-matching requires employee ID, date, and time of collection on tube). c. Royal Blue top with Purple stripe Metal-free EDTA tube used mainly for whole blood heavy metal testing (lead, manganese, chromium, cobalt). 6. ACD Solution A or B (Yellow stopper) 7.

BioAnalytics Sample Collection Tube Guide

EDTA anticoagulant lavender cap with white ring LTT-MINI Top Tube 0.5 mL Whole Blood Hematology, Fluids or Cytology Fill tube to appropriate fill line. (Proper blood to anticoagulant ratio is important for accurate results.) Gently invert the tube 5-10X to prevent clotting. Refrigerate. Do Not Freeze. Refrigerate. Do Not Freeze. Ship on cold packs.

Microtainer Tubes - BD

a syringe for blood transfer may also cause over or under filling of tubes, resulting in an incorrect blood-to-additive ratio and potentially incorrect analytic results. 5. If blood is collected through an intravenous (I.V.) line, ensure that line has been cleared of I.V. solution before beginning to fill blood collection tubes.

BD Vacutainer

The BD Best Practice Formulary (BPF), as it relates to BD Vacutainer® Blood Collection Tubes, was developed to provide customers with a condensed yet comprehensive array of BD Vacutainer® Blood Collection Tubes for virtually every clinical need. Each tube chosen for inclusion in the BPF meets

Specimen Collection Tubes - Quest Diagnostics

Collection Tubes Light blue tubes All plastic tubes other than light blue Clot 30-60 minutes Spin 10-15 minutes Pour into Transport Vial Label with Specimen Type Patient ID Patient ID Patient ID SERUM Do not use gel tubes for toxicology or drug testing * When using a winged blood collection set for venipuncture and a coagulation (citrate) tube

Antibody Test Kit - FDA

Sample collection tubes and venous whole blood (heparin, K 2-EDTA, and sodium citrate) samples. 11.3. Negative results do not preclude SARS -CoV-2 infection and should not be used as the

Laboratory Procedure Manual

A. Specimen collection The phlebotomist collects a 3- or 5-mL K3 EDTA tube on all SPs aged 1 year and older following established venipuncture protocol and procedures (a 1-2% dilution effect occurs in this liquid EDTA tube). B. Specimen preparation Run the CBC as soon as possible; there is no requirement to wait any length of time between drawing

PureLink Genomic DNA Kits - Thermo Fisher Scientific

(10 mM Tris-HCl, pH 9.0, 0.1 mM EDTA) 10 mL 50 mL RNase A (20 mg/mL) in 50 mM Tris-HCl, pH 8.0, 10 mM EDTA 1 mL 5 mL Proteinase K (20 mg/mL) in storage buffer (proprietary) 1 mL 5 mL PureLink® Spin Columns with Collection Tubes 50 each 5 × 50 each PureLink® Collection Tubes (2.0 mL) 100 5 × 100

Blood Collection Tube Top Colors

leukocytes (white blood cells) and thrombocytes (platelets) are stable in EDTA anticoagulated blood for up to 24 hours. Preparation of blood smears should be done within 3 hours after blood collection. EDTA tubes are used for testing whole blood in the clinical laboratory. EDTA K2 tubes are used for testing whole blood in molecular diagnostics.

C4. Procedure for serum and plasma separtion

1) Blood will be collected into purple top EDTA tubes and centrifuged (2000 rpm) at 4 degrees centigrade for 20 minutes. 2) After centrifugation using clean pipette technique place 1.0ml of plasma into